Device map
Device
number
SD1169
Orientation status
SD1170
Actual operation time
SD1171
Motor load factor
SD1172
Cumulative power
Position command (lower 16
SD1173
bits)

Position command (upper 16
SD1174
bits)

SD1175
Current position (lower 16 bits)
SD1176
Current position (upper 16 bits)
SD1177
Droop pulse (lower 16 bits)
SD1178
Droop pulse (upper 16 bits)
SD1179
Torque command
SD1180
Torque current command
SD1181
Motor output
SD1182
Feedback pulse
SD1184
Station number (PU connector)
Station number (RS-485 terminal
SD1185
block)
Communication station number
SD1186
(CC-Link)
SD1187
Remote output 1
SD1188
Remote output 2
SD1189
Remote output3
SD1190
Remote output 4
SD1191
PTC thermistor resistance value
SD1193
Cumulative pulse
Cumulative pulse overflow
SD1194
times

Cumulative pulse (control
SD1195
terminaloption)
Cumulative pulse overflow times
SD1196
(control terminal option)
SD1197
Energy saving effect
SD1198
Cumulative energy saving
SD1199
PID set point
SD1200
PID measured value
SD1201
PID deviation
SD1202
Second PID set point
SD1203
Second PID measured value
SD1204
Second PID deviation
28
PLC Function
Name
Stores the orientation status.

1 hour increments
0.1% increments
1 kWh increments
Stores the position command setting value (lower 16 bits).
Stores the position command setting value (upper 16 bits).
Stores the position feedback pulse value (lower 16 bits).

Stores the position feedback pulse value (upper 16 bits).

Stores the droop pulse value (lower 16 bits).

Stores the droop pulse value (upper 16 bits).

0.1% increments

0.1% increments

0.1 kW increments
Stores the feedback pulse quantity.

Stores the station number (PU connector).
Stores the station number (RS-485 terminal block).
Stores the communication station number (CC-Link).
Stores the analog remote output setting value 1.
Stores the analog remote output setting value 2.
Stores the analog remote output setting value 3.
Stores the analog remote output setting value 4.
Stores the PTC thermistor resistance value.
The cumulative number of pulses is displayed (monitor range: -
32767 to 32767) (For the vector control compatible plug-in

option).
The number of the cumulative pulse overflow times is
displayed(monitor range: -32767 to 32767) (For the vector
control compatible plug-in option).
The cumulative number of pulses is displayed (monitor range: -
32767 to 32767) (For the vector control compatible control

terminal option).
The number of the cumulative pulse overflow times is
displayed(monitor range: -32767 to 32767) (For the vector

control compatible control terminal option).
According to the parameter settings.
Stores the PID set point. The increment is 0.1%.
Stores the PID measured value. The increment is 0.1%.
Stores the PID deviation. The increment is 0.1%.
Stores the second PID set point. The increment is 0.1%.
Stores the second PID measured value. The increment is 0.1%.
Stores the second PID deviation. The increment is 0.1%.