3.18
Output (Y) status settings when STOP
status → RUN status
When changing from a state such as the RUN state to the STOP state, the RUN state output (Y) is stored in the PLC function.
When changing from the STOP state to the RUN state, the PLC function parameter settings can be configured to either re-
output the output (Y) or to output after operation execution.
"Output the output (Y) status before STOP"
After outputting the output (Y) status directly before the STOP state, the sequence program operation is executed.
"Clear the output (Y) (output after 1 scan)"
After clearing all outputs (Y) and executing the sequence program operation, the output (Y) is output.
Sequence program operation is executed.
Output (Y) status settings when STOP status → RUN status
STOP status to RUN status
Is output (Y) status at
STOP to be output?
YES
Output (Y) status at the time of
entering the STOP status is output.
NO
Output (Y) status is cleared.
Sequence program
3
101