Mitsubishi Electric A800 Programming Manual page 61

800 series, plc function
Hide thumbs Also See for A800:
Table of Contents

Advertisement

CC-Link I/O specifications
PLC function
Remote output
device number
device number
RY (n + 1) 0
to
RY (n + 1) 7
RY (n + 1) 8
RY (n + 1) 9
RY (n + 1) A
RY (n + 1) B
to
RY (n + 1) F
("n" indicates a value determined by the station number setting.)

These signal names are initial values. The functions of input signals can be changed using Pr.180 to Pr.186, Pr.188, and Pr.189.
The signals of RYn0, RYn1, and RYn9 cannot be changed. Signals changed using Pr.178, Pr.179, and Pr.187 are invalid.
For details on Pr.178 to Pr.189, refer to the Instruction Manual of the inverter.

For the FR-F800 series, no function is assigned in the initial setting.

These signal names are initial values. The functions of output signals can be changed using Pr.190 to Pr.196.
For details on Pr.190 to Pr.196, refer to the Instruction Manual of the inverter.

Output signals can be assigned using Pr.313 to Pr.315.
For details on the signals, refer to the description of Pr.190 to Pr.196 in the Instruction Manual of the inverter.
Remote register
PLC function
Address
device number
SD1062
RWwn
SD1063
RWwn + 1
SD1064
RWwn + 2
SD1065
RWwn + 3
("n" indicates a value determined by the station number setting.)
I/O figure
NOTE
• All remote registers are user areas and can be used freely.
60
CC-Link communication
Signal name
Reserved
Unused
(Initial data process
completion flag)
Unused
(Initial data process
request flag)
Error reset request flag
Reserved
Description
Registers for reading data
received from the master
station.
Devices for CC-Link (station No. 1)
RY00 to 0F
RX00 to 0F
RWw0
Master
RWw1
station
RWw2
RWw3
RWr0
RWr1
RWr2
RWr3
PLC function
Remote input
device number
device number
RX (n + 1) 0
to
RX (n + 1) 7
RX (n + 1) 8
RX (n + 1) 9
RX (n + 1) A
RX (n + 1) B
RX (n + 1) C
to
RX (n + 1) F
PLC function
Address
device number
SD1078
RWrn
SD1079
RWrn + 1
SD1080
RWrn + 2
SD1081
RWrn + 3
Inverter
Devices for built-in PLC function
X30 to 3F
Y30 to 3F
SD1062
SD1063
SD1064
SD1065
SD1078
SD1079
SD1080
SD1081
Automatically refreshed at every END.
Signal name
Reserved
Unused
(Initial data process
request flag)
Unused
(Initial data process
completion flag)
Error status flag
Remote station ready
Reserved
Description
Registers for writing data
to be sent to the master
station.