Execution condition
The SET and RST instructions are executed for each scan.
NOTE
• The number of steps is three when the following devices are used.
SET instruction ... Special relay (M)
RST instruction ... Special relay (M), all word devices
Program example
SET
RST
,
• Program that sets Y8 (ON) when X8 turns ON, and resets Y8 (OFF) when X9 turns ON.
Program that sets the data register content to 0.
X8 (SET input)
X9 (RST input)
Operations of SET and RST instructions
Coding
Coding
Stores X10 to 1F contents into D8 when X0
turns ON.
Resets D8 contents to 0 when X5 turns ON.
Sequence program
Sequence instructions