 Communication status LEDs
The FR-E800-SCE inverter has the network status LEDs equivalent to CC-Link IE TSN. Refer to the FR-E800 Instruction
Manual (Communication).
 Precautions for status LEDs
Communication status LEDs are not provided as included in the safety system. LED status may not be always correct. Do not
use them as operation indicators. They are used only to check the status for test operation and during troubleshooting.
6.1.2
Setting procedure for CC-Link IE TSN safety
communication functions
The following section describes settings for CC-Link IE TSN safety communication functions.
 Settings for CC-Link IE TSN
Refer to the FR-E800 Instruction Manual (Communication).
 Enabling CC-Link IE TSN safety communication functions
Set "1" in Pr.S002 Safety communication function selection to enable CC-Link IE TSN safety communication functions.
Refer to details of safety parameters
NOTE
• CC-Link IE TSN safety communication functions are not affected by the IP address specification for Ethernet command
source selection (Pr.1449 to Pr.1454).
 Setting parameters for safety sub-functions
Configure settings for safety sub-functions to be used.
Refer to details of safety parameters
 Safety communication settings using engineering software
1.
Use FR Configurator2 to set safety parameters Pr.S030 to Pr.S032. For details, refer to the Master Module User's
Manual.
Pr.
S030
CC-Link IE TSN safety communication function -
Transmission interval monitoring time
S031
CC-Link IE TSN safety communication function - Safety
certification code (upper)
S032
CC-Link IE TSN safety communication function - Safety
certification code (lower)
*1
Transmission interval for monitoring by the safety programmable controller to detect safety communication faults.
*2
Code used for certification of a device when it is connected to the safety programmable controller.
(page
14).
(page
14).
Name
*1
*2
*2
Initial value
Setting range
128 ms
128 to 1000 ms
65535
0 to 65535
65535
0 to 65535
6. Safety Communication Functions
6.1 CC-Link IE TSN safety communication functions
3
4
5
5
5
6
7
8
9
10
35