Mitsubishi Electric A800 Programming Manual page 21

800 series, plc function
Hide thumbs Also See for A800:
Table of Contents

Advertisement

Device map
Device number
Inverter operating status
SM1205
control flag (JOG)
Inverter operating status
SM1206
control flag (RT)
Inverter operating status
SM1207
control flag (AU)
Inverter operating status
SM1208
control flag (CS)
Inverter operating status
SM1209
control flag (MRS)
Inverter operating status
SM1210
control flag STP (STOP)
Inverter operating status
SM1211
control flag (RES)
SM1216
Inverter status (RUN)
SM1217
Inverter status (FWD)
SM1218
Inverter status (REV)
SM1219
Inverter status (SU)
SM1220
Inverter status (OL)
SM1221
Inverter status (IPF)
SM1222
Inverter status (FU)
SM1223
Inverter status (ALM)
SM1224
Inverter status (LF)
SM1225
Inverter status (DO0)
SM1226
Inverter statusDO1)
SM1227
Inverter status (DO2)
SM1228
Inverter status (DO3)
SM1229
Inverter status (DO4)
SM1230
Inverter status (DO5)
SM1231
Inverter status (DO6)
SM1232
Inverter status (RA1)
SM1233
Inverter status (RA2)
SM1234
Inverter status (RA3)
SM1235
Safety monitor (terminal SO)
Inverter operating status
SM1255
control selection
2-word parameter access
SM1256
notice
20
PLC Function
Name
Flag used for controlling the inverter terminal JOG.
Flag used for controlling the inverter terminal RT.
Flag used for controlling the inverter terminal AU.
Flag used for controlling the inverter terminal CS.

Flag used for controlling the inverter terminal MRS.
Flag used for controlling the inverter terminal STP (STOP).
Flag used for controlling the inverter terminal RES.
Inverter running
Forward rotation
Reverse rotation
Up to frequency
Overload alarm
Instantaneous power failure/undervoltage
Output frequency detection
Fault output
Warning output
Stores the operating status of an output terminal function assigned by
Pr.313.
Stores the operating status of an output terminal function assigned by
Pr.314.
Stores the operating status of an output terminal function assigned by
Pr.315.
Stores the operating status of an output terminal function assigned by
Pr.316.
Stores the operating status of an output terminal function assigned by
Pr.317.
Stores the operating status of an output terminal function assigned by
Pr.318.
Stores the operating status of an output terminal function assigned by
Pr.319.
Stores the operating status of an output terminal function assigned by
Pr.320.
Stores the operating status of an output terminal function assigned by
Pr.321.
Stores the operating status of an output terminal function assigned by
Pr.322.
The safety monitor (terminal SO) status is stored.
This is turned ON when no internal safety circuit failure has occurred.
Select the inverter operating status of SM1200 to SM1211 and SD1148.
OFF: Special relay selection
ON: Special register selection
Turned ON when parameter read for the inverter is executed using X28 to
X2B, Y28 to Y2B, and the object was 2-word parameter.
OFF: Read is completed as 1-word parameter.
ON: Read is completed as 2-word parameter.