Mitsubishi Electric A800 Programming Manual page 27

800 series, plc function
Hide thumbs Also See for A800:
Table of Contents

Advertisement

Device map
Device
number
SD520
Current scan time
SD521
SD524
Minimum scan time
SD525
SD526
Maximum scan time
SD527
SD1062
to
Remote register
SD1093
SD1133
Output frequency monitor
SD1134
Output current monitor
SD1135
Output voltage monitor
SD1136
Faults history 1, 2
SD1137
Faults history 3, 4
SD1138
Faults history 5, 6
SD1139
Faults history 7, 8
SD1140
Operation mode setting read
SD1141
Set frequency read (RAM)
SD1142
Set frequency read (EEPROM)
SD1143
Operation mode setting write
SD1144
Set frequency write (RAM)
SD1145
Set frequency write (EEPROM)
SD1146
Fault record batch clear
SD1147
Parameter clear
SD1148
Inverter operating status control
26
PLC Function
Name
Scan time is stored at every END, and is constantly updated.
(Measured in 100 μs increments)
SD520: Stores the millisecond places (Stored range: 0 to 65535)
SD521: Stores the microsecond places (Stored range: 0 to 900)
Minimum scan time is stored at every END.
(Measured in 100 μs increments)
SD524: Stores the millisecond places (Stored range: 0 to 65535)
SD525: Stores the microsecond places (Stored range: 0 to 900)
Maximum scan time is stored at every END.
(Measured in 100 μs increments)
SD526: Stores the millisecond places (Stored range: 0 to 65535)
SD527: Stores the microsecond places (Stored range: 0 to 900)
Special register for communicating with the master station in
CC-Link.
Present output frequency is stored. The increment is 0.01 Hz.
Present output current is stored. The increment is 0.01 A.
Present output voltage is stored. The increment is 0.1 V.
Faults in the inverter are stored in the order of occurrence.
Stores the present operation mode.
Reads and stores the set frequency (RAM).
Reads and stores the set frequency (EEPROM).
Sets the operation mode to be changed.
Sets the running frequency (RAM).
Sets the running frequency (EEPROM).
Clears the faults history when H9696 is written.
H9696 write: parameter clear
H9966 write: all clear
H5A5A write: parameter clear except for communication
parameters
H55AA write: all clear except for communication parameters
While communicating with FR Configurator2, clear the
parameters using H5A5A or H55AA.
Turn ON/OFF the corresponding bit to control the inverter
operating status.
All initial values are set as "0". When SM1255 is OFF, this
function is disabled.
Description
b15
b12 b11
b8 b7
b4 b3
Invalid
Page
-
-
-
-
-
-
59
32
33
36
37
37
39
39
40
41
41
b0
0:OFF
1:ON

STF
42

STR
RH
RM
RL
JOG
RT
AU
CS
MRS
STP (STOP)
RES

Hide quick links: