Download  Print this page

Mitsubishi Electric A800 Programming Manual Page 28

800 series, plc function.
Hide thumbs

Advertisement

Device
Name
number
Inverter operating status control
SD1149
enable/disable setting
SD1150
Inverter parameter access error
SD1151
Inverter status
SD1152
Frequency setting value
SD1153
Running speed
SD1154
Motor torque
SD1155
Converter output voltage
SD1156
Regenerative brake duty
SD1157
Electric thermal relay load factor
SD1158
Output power peak value
Converter output voltage peak
SD1159
value
SD1160
Input power
SD1161
Output power
SD1162
Input terminal status
SD1163
Output terminal status
SD1164
Load meter
SD1165
Motor excitation current
SD1166
Position pulse

SD1167
Cumulative energization time
The inverter operating status control by SD1148 and SM1200 to
SM1211 can be enabled/disabled by turning ON/OFF the
corresponding bit.
The bit table is the same as SD1148.
All initial values are set to "0" (invalid).
Input through external terminals is always enabled for the SQ
signal. (The SQ signal cannot be controlled with SD1149 bits.)
Stores the error number generated when parameter or data
stored in the special register was not successfully reflected to
the inverter.
Operating status of the inverter is stored.
b15
Terminal SO status
0.01 Hz increments
1 (0.1) r/min increments
Pr.811 Set resolution switchover enables 0.1 r/min unit
indication

0.1% increments
0.1 V increments
0.1% increments

0.1% increments
0.01 A increments
0.1 V increments
0.01 kW increments
0.01 kW increments
Details of input terminal status
b15
b12 b11
Details of output terminal status
b15
0.1% increments
0.01 A increments
Stores the encoder position pulse
1 hour increments
Description
b8 b7
b4 b3
b0
0:OFF
1:ON
Inverter running(RUN)
Forward running
Reverse running
Up to frequency(SU)
Overload alarm(OL)
Instantaneous power failure
/undervoltage(IPF)
Output frequency
detection(FU)
Fault output(ALM)
Alarm output(LF)
b8 b7
b4 b3
b0
0:OFF
1:ON
STF
STR
AU
RT
RL
RM
RH
JOG
MRS
STP (STOP)
RES
CS
b7
b4 b3
b0
0:OFF
1:ON
RUN
SU
IPF
OL
FU
ABC1
ABC2
PLC Function
Device map
Page
43
44
44
-
-
-
-
-
-
-
-
-
-
-
1
-
-
-
-
-
27

Advertisement

Table of Contents

This manual is also suitable for:

F800

Comments to this Manuals

Symbols: 0
Latest comments: