B.3.2
prtdiag Command
The prtdiag command displays configuration and diagnostic information. The diagnostic
information identifies any failed component.
The prtdiag command is located in the /usr/platform/platform-name/sbin/
directory.
Note – The prtdiag command might indicate a slot number different than that identified
elsewhere in this document. This is normal.
B.3.2.1
prtdiag Command Options
TABLE B-14
troubleshooting.
Options for prtdiag
TABLE B-14
Option
Description
No option
Lists components.
Verbose mode. Displays the time of the most recent
-v
AC power failure and the most recent hardware fatal
error information.
describes options for the prtdiag command and how those options can help
How It Can Help
Identifies CPU timing and PCI cards
installed.
Provides the same information as no option.
Additionally lists fan status, temperatures,
ASIC, and PROM revisions.