4. Confirm that the XSCF Shell prompt (XSCF>) is displayed.
3.7.4
Verifying the Configuration
Verify the hardware configuration by following the procedure below on the administration
console.
Note – For details of each command, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference Manual.
1. Type the showhardconf command at the XSCF Shell.
All the components mounted in the OPL system and their status information is displayed.
For details on the showhardconf command and its output, see
the showhardconf Command" on page
2. Confirm for each unit name that an asterisk (*) is not displayed on the left of the
unit name.
3. Confirm that XSCFU#0 is Active, XSCFU#1 is Standby.
4. See the list of pre-mounted components and check the information.
5. Type the showhardconf -u command at the XSCF Shell.
The number of installed FRUs is displayed. For details on the showhardconf command
and its output, see
6. Check that the configuration displayed is equivalent to the shipping list.
7. Type the console -d 0 command from the XSCF Shell.
This command switches the prompt from the XSCF console (XSCF>) to the domain
console (the OS console) and the ok prompt is displayed.
8. Type the probe-scsi-all command at the ok prompt.
9. Verify that the installed CD-RW/DVD-RW drive unit, tape drive unit, and hard disk
units are recognized.
10. Type the show-devs command at the ok prompt.
11. Confirm that the installed PCI card has been recognized.
12. Press the Enter, "#" (default escape character) , and "." (period) keys.
The #. key sequence switches the prompt from the domain console to the XSCF console.
3-58
SPARC Enterprise M8000/M9000 Servers Installation Guide • October 2012
Section B.2.1, "Using the showhardconf Command" on page
B-3.
Section B.2.1, "Using
B-3.