NWIDth
NWIDth
command/query
The
:MEASURE:NWIDTH
command places the instrument in the
continuous
measurement mode and
starts
a
NWIDTH
measurement.
The
NWIDTH
query measures and outputs the
width of the
first negative
pulse on
screen
using the
50%
levels
with Standard
measurements
selected.
If
User Defined
measurements are selected, then the measurement
is
made
at
the mid threshold value.
The algorithm
is:
if
the
first
edge on screen
is
rising
then
width
=
(time at
second rising edge
time at
First
falling edge)
else
width
=
(time
at
First
rising
edge
-
time at first falling edge)
Command
Syntax:
:MEASure:NWiDth
Example:
OUTPUT 707;":MEAS:NW1DTH"
Query Syntax:
:MEASure:NWiDth?
Returned Format:
[:MEASure:NWiDth]
<
value
>
<NL>
Where:
<
value
>
::
=
negative pulse width
in
seconds (exponential
-
NR3 format)
Example:
DIM Nwd$[50]
OUTPUT
707;":MEASURE:NWIDTH?"
ENTER 707;Nwd$
PRINT
Nwd$