POS MV V5 Installation and Operation Guide
Installation
If the POS MV V5 receives power from an Uninterruptible Power Supply (UPS), make certain that it is
operating at the correct voltage; refer to the Power Requirements description on page 2-3 for details.
Good grounding practices are essential for proper operation of the POS MV V5 systems.
COM (1) through COM (4/5) Interface
P
HYSICAL
Serial cables should not exceed 15 m [~49 ft] in length. To ensure data integrity, use high quality RS-232
cable with its shielding connected through the back shell to ground at both cable ends. Table 7, page 2-
18 and Table 9, page 2-19 provide COM port connector assignments and mapping for the POS MV V5-1
PCS. Table 3 provides the same information for the POS MV V5 PCS.
2-12
I
NTERFACE
Table 3: COM Connectors Pin Assignment - POS MV V5
Pin
Pin Description
N/C
(port 1 & 2)
1
RXa
(port 3 & 4)
RX
(port 1 & 2)
2
RXb
(port 3 & 4)
TX
(port 1 & 2)
3
TXb
(port 3 & 4)
N/C
(port 1 & 2)
4
TXa
(port 3 & 4)
5
GND
(port 1 through 4)
6
N/C
(port 1 through 4)
RTS
(port 1 & 2)
7
N/C
(port 3 & 4)
CTS
(port 1 & 2)
8
N/C
(port 3 & 4)
9
N/C
(port 1 through 4)
POS MV V5 Rear Panel
DE-9P Male Connector
Signal
Signal Type
Direction
N/A
N/A
RS-422
Input
RS-232
Input
RS-422
Input
RS-232
Output
RS-422
Output
N/A
N/A
RS-422
Output
N/A
N/A
N/A
N/A
RS-232
Output
N/A
N/A
RS-232
Input
N/A
N/A
N/A
N/A
1
5
6
9
Need help?
Do you have a question about the POS MV V5 and is the answer not in the manual?