J1 - Ac Input Control Power High Power Ac Models - Kollmorgen S20260 Installation Manual

S200 series
Table of Contents

Advertisement

Connector Pinout And Descriptions
7.3 J1 – AC I
NPUT
Models: S21260-xNS
Pin
J1-1
PE (Protective Earth) – Must be tied back to central earth bar.
J1-2
C2 CTRL VAC – Logic control Power. Use 120 or 240Vac.
J1-3
C1 CTRL VAC – Logic Control Power. Use 120 or 240 Vac.
Please refer to the Specifications section for fusing and rating information.
It is the customer's responsibility to supply appropriate fuses or circuit
breakers in the J1 AC drive power lines to comply with local electrical
NOTE
codes.
For maximum line droop tolerance connect logic power to 230Vac instead of 115Vac
NOTE
To avoid damage to the connector and drive, NEVER plug or unplug J1
with power applied.
CAUTION
Mating Connector Information:
Screw Terminal Connector
OR Spring Cage Clamp Connector
OR Crimp Connector
30
4/13/2012
C
P
ONTROL
PE
Description
12 – 24 AWG Wire Range, Phoenix MSTB2,5/3-STF-5,08-BK
12 – 24 AWG Wire Range, Phoenix FKC 2,5/3-SFT-5,08-BK
Crimp Shell: 14-20 AWG Wire Range, Phoenix MSTBC 2,5/3-STZF-5,08-BK
Crimp Contact: 14-16 AWG Wire Range, Phoenix MSTBC-MT 1,5-2,5
Crimp Contact: 18-20 AWG Wire Range, Phoenix MSTBC-MT 0,5-1,0
Refer to www.phoenixcon.com.
H
P
OWER
IGH
OWER
C2
C1
Kollmorgen
AC M
ODELS