9.4.2 Typical Wiring with Sourcing Switches

Customer's Power Supply
4 to 30Vdc
+
Customer's Switching
(May be Solid State)
Field Wiring
The above diagram shows typical wiring for Sourcing switches. The Switches supply the source of current through
the S200 Position Node input. These devices may be solid state and are sometimes called PNP devices.
Current drain for the inputs is identified in the following table.

9.4.3 Wiring DINP5 and DINP10

As noted DINP5 and DINP10 are high speed opto-isolated input devices that do not have a connection to a
common rail. They are designed for 5 volt operation and the polarity of the power supply used is critical for
functionality. Not having a common rail connection the inputs can be wired for sourcing or sinking according to the
need of the application.
Customer's Power Supply
5Vdc
Field Wiring
44
J4-1
(J12-1)
-
J4-2
(J12-2)
J4-3
(J12-3)
J4-4
(J12-4)
J4-5
(J12-5)
Input Voltage (±)
4.0 volts
5.0 volts
12 volts
24 volts
30 volts
J4-10
(J12-10)
J4-11
(J12-11)
4/13/2012
S200 Position Node Internal Equiv
Circuits
Internal Opto-Isolators
Input Current (±)
0.65 mA
0.95 mA
2.5 mA
5.3 mA
6.7 mA
S200 Position
Node Internal
Hi-Speed Opto-Isolator
Kollmorgen
DINP1
(Enable)
(DINP6)
DINP2
(DINP7)
DINP3
(DINP8)
DINP4
(DINP9)
DINP5
(DINP10)