Input Power Specifications - Kollmorgen S20260 Installation Manual

S200 series
Table of Contents

Advertisement

Specifications
3.2 I
P
NPUT
OWER
Input Voltage Range (RMS)
Ride Through Time for AC Line Drop
Input Voltage Range (RMS) VAC
Phases
Transformer Suggested KVA
Maximum AC Line KVA
240 VAC Input Nominal Bus Voltage
120 VAC Input Nominal Bus Voltage
BUS Under voltage Fault
BUS Over voltage (BusOV) Fault
BUS Regen Voltage
Worse Case Inrush Peak Current at 240 VAC
Inrush pulse width
240 VAC 3 Phase
(A
)
RMS
240 VAC 1 Phase
(A
)
RMS
120 VAC 1 Phase
(A
)
RMS
Control Power Applied to Drive Operational
9
S
PECIFICATIONS
AC Control Power Supply
AC Motor Power Supply
90 to 265
1 or 3
2 to 3
1
100
1
Maximum AC Line is specified to limit the mains surges to the drive.
AC Bus Voltage and Faults
320 VDC
155 VDC
Factory Default is None
407 VDC + 5%
= 0.974*BusOV = 397 VDC Nominal
AC Inrush Current & Fusing
Recommended Fusing Line Inputs
Type – 250 VAC Time Delay Fuse
S20260
FRN-R-5
FRN-R-5
FRN-R-5
AC Power on Delay
4/13/2012
85 VAC to 265 VAC single phase
47 to 63 Hz
120 VDC to 375 VDC
85 VAC 60 Hz > 0.78 60 Hz cycles
120 VAC 60 Hz > 3.3 60 Hz cycles
240 VAC 60 Hz >18.5 60 Hz cycles
140 A 0-p
1.5 ms
S20360
S20660
FRN-R-8
FRNR-15
FRN-R-10
FRN-R-20
FRN-R-10
FRN-R-20
1.25 seconds
Kollmorgen
S21260
FRN-R-25
FRN-R-30
-
S200 Position Node Installation Guide