Environmental Specifications; Smart Feedback Device (Sfd) - Kollmorgen S20260 Installation Manual

S200 series
Table of Contents

Advertisement

Specifications
3.7 E
NVIRONMENTAL
Operating Temperature (° C) – Full
Rating
Operating Temperature (° C) – Derated
Linearly Derate Continuous Current to
o
67% of 40
C Rating
Pollution Degree
Storage Temperature (° C)
Humidity (% non-condensing)
Altitude
3.8 S
F
MART
EEDBACK
Resolution/Rev (arc min)
Repeatability (arc min RMS)
Noise
No Filtering (arc min RMS)
150 Hz Single Pole Filtered (arc min
RMS)
10 Hz Single Pole Filtered (arc min
RMS)
DC Offset Temperature Drift
Absolute Accuracy
AKM1 (arc min)
AKM2 or 3, 4 (arc min)
Communications Update Period (µs)
14
4/13/2012
S
PECIFICATIONS

Environmental Specifications

0 to 40
40 – 50
2
-20 to 70
10 to 90
<1500 m (5000 feet)
D
(SFD)
EVICE
SFD (Smart Feedback Device)
24 bits = 0.0013
< ± 2
-17
< 2
-18
< 2
-19
< 2
-18
< 2
-10.3
± 2
-11.1
± 2
51.2
-19
Rev = ± 0.04
Rev RMS = 0.16
Rev RMS = 0.08
Rev RMS = 0.02
Rev/° C = 0.08 arc min/° C
Rev = ±17
Rev = ±10
S200 Position Node Installation Guide
Kollmorgen

Advertisement