Cfgremotehosts - Dell PowerEdge M1000e Reference Manual

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

The current MAC address of NIC. For example, 00:12:67:52:51:A3.
Default

cfgRemoteHosts

This group provides properties that allow configuration of the SMTP server for email alerts.
This group enables/disables and configures firmware updates, NTP, remote syslogging and SMTP email alerting.
Use this object with the config or getconfig subcommands.
To use this object property, you must have the Chassis Configuration Administrator privilege.
The following sections provide information about the objects in the cfgRemoteHosts group.
cfgRhostsFwUpdateTftpEnable (Read or Write)
Enables or disables firmware update from a network TFTP server.
Description
1 (TRUE)
Legal Values
0 (FALSE)
1
Default
cfgRhostsFwUpdateIpAddr (Read or Write)
Specifies the network TFTP server IPv4 or IPv6 address that is used for TFTP firmware update operations.
Description
A string representing a valid IPv4 or IPv6 address. For example, 192.168.0.61
Legal Values
For IPv4, it is 0.0.0.0
Default
cfgRhostsFwUpdatePath (Read or Write)
Specifies TFTP path where firmware image file exists on the TFTP server. The TFTP path is relative to the
Description
TFTP root path on the TFTP server.
A string with a maximum length of 255 ASCII characters.
Legal Values
Default
<blank>
cfgRhostsSmtpServerIpAddr (Read or Write)
The IPv4 or IPv6 address of the network SMTP server.
Description
The SMTP server transmits email alerts from CMC if the alerts are configured and enabled.
A string representing a valid SMTP server IPv4 or IPv6 address. For example: 192.168.0.
Legal Values
localhost.localdomain
Default
86
NOTE: The server may still require you to specify the drive (for example, C:).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents