Setniccfg - Dell PowerEdge M1000e Reference Manual

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the server in slot 1.

setniccfg

Description
Sets the iDRAC or CMC IP address for static and DHCP modes.
To run this subcommand, you must have the Configure Chassis Administrator privilege.
Synopsis
racadm setniccfg [-m <module>] -d [-6]
racadm setniccfg [-m <module>] -s <ipAddress> <netmask> <gateway>
racadm setniccfg [-m <module>] -s -6 <ipv6Address> <prefixlen> <gateway>
racadm setniccfg [-m <module>] -v [<vlan_id> <vlan_priority>]
racadm setniccfg [-m chassis] -o
racadm setniccfg –p [-6]
racadm setniccfg [-m <module>] -k [<speed> <duplex>]
racadm setniccfg [-i <slot>] -v [<vlan_id> <vlan_priority>]
-d — Enables DHCP for the NIC. It is enabled by default.
Input
-d6 — Enables AutoConfig for the NIC (default is disabled).
-s — Enables static IP settings. The IPv4 address, netmask, and gateway must be specified. Otherwise,
the existing static settings are used. <ipaddress>, <netmask>, and <gateway> must be typed as
dot-separated strings.
racadm setniccfg -s 192.168.0 255.255.255.0 192.168.0
-s6 — Enables static IPv6 settings. The IPv6 address, Prefix Length, and the IPv6 Gateway can be
specified.
-o — Enable or disable NIC.
-m<module> — Must be one of the following values:
– chassis — Default state if -m is not specified
– server–<n>: where n=1–16
– server–<nx>: where n=1–8; x=a–d (lower case)
– switch–<n>: where n=1–6
-v — VLAN settings has following legal values: no arguments imply remove VLAN tag, not compatible with
server–nx (for example "server–4b") notation <vlan_id>=between 1 and 4000, 4021 and 4094, inclusive
<vlan_priority>=between 0 and 7, inclusive.
-p — Disables IPv4(default) or IPv6 protocol.
-k — Option has following legal values: no arguments imply autonegotiate <speed>=10, 100 <duplex>
=half, full.
68
NOTE: The setled command generates an error when run on the extension slot of a multi-slot
server.
NOTE: The command helps to modify network configuration properties.
NOTE: The terms NIC and Ethernet management port may be used interchangeably.
NOTE:
-o, -k, -p: These options can be specified for chassis only
-6: Sets static IPv6 addresses (with -soption). Enables autoconfig for IPv6 (with-d option) disables
IPv6 (with-p option) can be specified for chassis or servers.
-v: When performing on a switch, release and renew any DHCP lease on that port for changes to
take effect.