cmc-<n> — where n=1, 2
•
fan-<n> — where n=1–9
•
ps-<n> — where n=1–6
•
chassis
•
kvm
•
lcd
•
To display the entire log (Critical, Warning and Informational messages) for all modules.
Examples
racadm getactiveerrors
Module ID
Severity
Message
Module ID
Severity
Message
Module ID
Severity
Message
•
To display Critical error messages for all the components.
racadm getactiveerrors –s critical
Module ID
Severity
Message
Module ID
Severity
Message
Module ID
Severity
Message
•
To display critical error messages for server–1.
racadm getactiveerrors
Module ID
Severity
Message
•
The error message displayed for invalid syntax.
racadm getactiveerrors –z cmc-1
ERROR: The syntax of the command specified is not correct.
•
The error message displayed for invalid parameter.
racadm getactiveerrors –m server-80
ERROR: The syntax of the command specified is not correct.
•
To display entire information log.
racadm getactiveerrors -s info
Module ID = 1
Severity = Critical
Message = A fabric mismatch deteceted for mezzanine card B1.
Module ID = ps-1
28
NOTE: A few of the informational messages are applicable for more than one module. To avoid
repetition of the same message for different modules, only one such informational message is
displayed for the default command racadm getactiveerrors. When an -m option is used on
another server or switch, the informational message is displayed, if applicable.
After you run this command, the full-height, half-height, and the quarter-height servers and switches are
automatically checked for informational messages (in the same order as mentioned here).
= 1
= Critical
= The storage battery has failed.
= 10
= Critical
= General failure after video.
= ps-6
= Critical
= The power input for power supply 6 is lost.
= 1
= Critical
= The storage battery has failed.
= 10
= Critical
= General failure after video.
= ps-6
= Critical
= The power input for power supply 6 is lost.
= 1
= Critical
= The storage battery has failed.
–s critical –m server-1