Getniccfg - Dell PowerEdge M1000e Reference Manual

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

IO-Cable
Present
FPC-Cable
Present
NOTE: A power state of "Primary" denotes Active CMC.

getniccfg

Displays the current NIC settings.
Description
racadm getniccfg [-m <module>]
Synopsis
–m <module> must be one of the following values:
Input
The getniccfg subcommand displays an appropriate error message if the operation is not successful.
Output
Otherwise, the output is displayed in the following format:
NIC Enabled
IPv4 Enabled
DHCP Enabled
Static IP Address
Static Subnet Mask
Static Gateway
Current IP Address
Current Subnet Mask
Current Gateway
IPv6 Enabled
Autoconfiguration Enabled
Static IPv6 Address
Static IPv6 Gateway
Link Local Address
Current IPv6 Address 1
Current IPv6 Gateway
Speed
Duplex
Redundant mode
VLAN Enable
VLAN ID
VLAN priority
Example
ON
ON
chassis : Default state if -m is not specified.
server-<n> : where n=1–16
server-<nx> : where n=1–8; x = a, b, c, d (lower case)
switch-<n> : where n=1–6
NOTE: IPv6 information is displayed only if IPv6 is enabled in iDRAC.
Display CMC network settings
racadm getniccfg -m chassis
OK
noble01
OK
noble01
=1
=1
=1
=192.168.0.120
=255.255.255.0
=192.168.0.1
=192.168.0.32
=255.255.255.0
=192.168.0.1
=0
=1
=::
=::
=::
=::
=::
=Autonegotiate
=Autonegotiate
=0
=0
=1
=0
N/A
N/A