Cfgactivedirectory - Dell PowerEdge M1000e Reference Manual

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

# cfgServerRootPassword=******** (Write-Only)
cfgServerFirstBootDevice=0
cfgServerBootOnce=1
# cfgServerPowerConsumption=84

cfgActiveDirectory

This group contains parameters to configure CMC Active Directory feature.
Use this object with the config or getconfig subcommands.
To use this object property, you must have the Chassis Configuration Administrator privilege.
NOTE: You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable
object, use the —o option.
The following sections provide information about the objects in the cfgActiveDirectory.
cfgADRacDomain (Read or Write)
Active Directory Domain in which CMC resides.
Description
Any printable text string of up to 254 characters, with no white space.
Legal Values
Default
<blank>
cfgADRacName (Read or Write)
Name of CMC as recorded in the Active Directory forest.
Description
Any printable text string of up to 254 characters, with no white space.
Legal Values
Default
<blank>
cfgADRootDomain (Read or Write)
Specifies the root domain of the domain forest.
Description
Any printable text string of up to 254 characters, with no white space.
Legal Values
Default
<blank>
cfgADEnable (Read or Write)
Enables or disables Active Directory user authentication on CMC.
Description
If this property is disabled then either local CMC or LDAP authentication may be used for user login.
1 (TRUE)
Legal Values
0 (FALSE)
0
Default
108

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents