1 (Full Duplex)
1
Default
cfgNetTuningNicMtu (Read or Write)
Indicated the maximum size of units in bytes transmitted by NIC.
Description
576–1500
Legal Values
1500
Default
NOTE: IPv6 requires a minimum MTU of 1280. If IPv6 is enabled, and cfgNetTuningMtu is set to a lower value, the CMC
uses an MTU of 1280.

cfgRacSecurity

This group is used to configure settings related to CMC SSL certificate signing request (CSR) feature. The properties in this group
must be configured before generating a CSR. Use this object with the config or getconfig subcommands. To use this object property,
you must have the Chassis Configuration Administrator privilege.
For more information about generating certificate signing requests, see the subcommand sslcsrgen.
For the country code, go to the link http://www.iso.org/iso/country_codes/iso_3166_code_lists.htm
The following sections provide information about the objects in the cfgRacSecurity group.
cfgRacSecCsrCommonName (Read or Write)
Specifies the CSR Common Name (CN) that must be an IP or CMC name as given in the certificate.
Description
A string of up to 254 characters.
Legal Values
<blank>
Default
cfgRacSecCsrOrganizationName (Read or Write)
Specifies the CSR Organization Name (O).
Description
A string of up to 254 characters.
Legal Values
<blank>
Default
cfgRacSecCsrOrganizationUnit (Read or Write)
Specifies the CSR Organization Unit (OU).
Description
A string of up to 254 characters.
Legal Values
<blank>
Default
134