Cfgserverinfo - Dell PowerEdge M1000e Reference Manual

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

cfgRacTuneSshPort=22
cfgRacTuneIpRangeEnable=0
cfgRacTuneIpRangeAddr=192.168.1.1
cfgRacTuneIpRangeMask=255.255.255.0
cfgRacTuneIpBlkEnable=0
cfgRacTuneIpBlkFailCount=5
cfgRacTuneIpBlkFailWindow=60
cfgRacTuneIpBlkPenaltyTime=300
# cfgRacTuneTimezoneOffset=-18000
# cfgRacTuneDaylightOffset=3600
cfgRacTuneTimezoneOffset (Read Only)
This object property is read only. Specifies the difference in number of seconds, from the UTC/GMT. This value
Description
is negative if the current time zone is west of Greenwich.
None
Legal Values
0
Default
Example
racadm getconfig -g cfgRacTuning
cfgRacTuneRemoteRacadmEnable=1
cfgRacTuneWebserverEnable=1
cfgRacTuneHttpPort=80
cfgRacTuneHttpsPort=443
cfgRacTuneTelnetPort=23
cfgRacTuneSshPort=22
cfgRacTuneIpRangeEnable=0
cfgRacTuneIpRangeAddr=192.168.1.1
cfgRacTuneIpRangeMask=255.255.255.0
cfgRacTuneIpBlkEnable=0
cfgRacTuneIpBlkFailCount=5
cfgRacTuneIpBlkFailWindow=60
cfgRacTuneIpBlkPenaltyTime=300# cfgRacTuneTimezoneOffset=-18000#
cfgRacTuneDaylightOffset=3600
cfgRacTuneWebserverEnable (Read or Write)
Enables or disables the web server. If this property is disabled then it is not accessible using client web
Description
browsers. This property has no effect on the Telnet/SSH or racadm interfaces.
1 (TRUE)
Legal Values
0 (FALSE)
1
Default

cfgServerInfo

This group allows you to display and configure a server in the chassis.
Use this object with the config or getconfig subcommands.
To use this object property, you must have the Chassis Configuration Administrator privilege.
NOTE: You can configure a setting does not have the hash sign (#) prefixed in the output. To modify a configurable
object, use the —o option