Installation And Configuration WARNING: Before performing the following procedure, review the safety instructions that came with the blade server or enclosure. NOTE: The system is intended for restricted access location in accordance with the National Electric Code, National Standards Institute (ANSI/National Fire Protection Association (NFPA) 70. Unpacking The System Unpack your blade server or enclosure and identify each item.
Figure 2. Installing a Sleeve NOTE: Before you install or remove a sleeve from the enclosure, ensure that the top slot of the sleeve (Blade a) is empty. You can install a blade in the top slot (Blade a) after you install the sleeve in the enclosure. Remove the orange cover from the sleeve handle.
Figure 4. Installing a Half-Height Blade NOTE: The above figure shows installation of a half-height blade. The procedure for installing a full-height blade is identical to installing a half-height blade. Beginning at the top, slide the blades into the enclosure from left to right. When the blade is securely installed, the blade handle returns to the closed position.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Be sure the operating system is installed before installing hardware or software not purchased with the system. NOTE: See dell.com/ossupport for the latest information on supported operating systems.
Before using your system, read the Dell Software License Agreement that came with your system. You must consider any media of Dell-installed software as BACKUP copies of the software installed on your system’s hard drive. If you do not accept the terms of the agreement, call the customer assistance telephone number. For customers in the United States, call 800-WWW-DELL (800-999-3355).
Col. Lomas Altas 11950 México, D.F. Model number: BMX01 Supply voltage: 100 V CA to 240 V CA (with 2700 W AC power supply units) or –(48–60) V CC (with 2700 W DC power supply units) 200 V CA to 240 V CA (with 3000 W AC power supply units) Frequency: 50 Hz/60 Hz or N/A Current consumption:...
Page 10
Power — Enclosure Heat dissipation 1200 BTU/hr (maximum) NOTE: Heat dissipation is calculated using the power supply wattage rating. Maximum inrush current Under typical input voltage conditions and over the entire system ambient operating range, the inrush current may reach 55 A per power supply for 10 ms or less.
Page 11
Physical — Blades Depth 48.6 cm (19.2 inch) Weight (maximum) 14.5 kg (31.9 lb) PowerEdge M710 and M610x Height 38.5 cm (15.2 inch) Width 5 cm (2 inch) Depth 48.6 cm (19.2 inch) Weight (maximum) 11.1 kg (24.5 lb) PowerEdge M710HD and M620 Height 18.9 cm (7.4 inch) Width...
Page 12
Weight (maximum) 200.5 kg (442 lb) Weight (empty) 44.6 kg (98.1 lb) Environmental NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. Temperature Maximum Temperature Gradient (Operating and 20 °C/h (36 °F/h) Storage) Storage Temperature Limits –40 °C to 65 °C (–40 °F to 149 °F)
Page 13
Environmental 40 °C to 45 °C (104 °F to 113 °F) Maximum temperature is reduced by 1 °C/125 m (1 °F/228 ft) above 950 m (3,117 ft). Particulate Contamination NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination.