Dell PowerEdge M1000e Reference Manual page 120

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

43221 BTU/hr
Default
cfgChassisPowerCapFBTU (Read or Write)
Indicates the maximum power consumption limit (in BTU/hr) for the entire chassis. Use
Description
cfgChassisCapFBTU when power consumption changes regardless of whether server throttling is required.
The command generates an error if the value for this setting is lower than the minimum power required for the
chassis configuration.
9264–56931 BTU/hr
Legal Values
56931 BTU/hr
Default
cfgChassisPowerCapPercent (Read or Write)
Indicates the power consumption limit as a percentage. The percentage is computed mathematically as the
Description
minimum power + (percent * (maximum power — minimum power)). The command generates an error if
server throttling is necessary to achieve the power goal based on the value for this setting.
16–100
Legal Values
100
Default
cfgChassisPowerCapFPercent (Read or Write)
Indicates the power consumption limit as a percentage. The percentage is computed mathematically as the
Description
minimum power + (percent * (maximum power — minimum power)). Use
cfgChassisPowerCapFPercent when power consumption is changes regardless of whether server
throttling is required.
16–100
Legal Values
100
Default
cfgChassisRedundancyPolicy (Read or Write)
Sets the redundancy policy of the chassis.
Description
0 — No redundancy
Legal Values
1 — Grid redundancy
2 — Power supply redundancy
0 — No redundancy
Default
120
NOTE: If the specified percent is lower than the minimum value, the CMC sets the value to the
minimum value.
NOTE: If the specified percent is lower than the minimum value, the CMC sets the value to the
minimum value.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents