Getactiveerrors - Dell PowerEdge M1000e Reference Manual

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

Signed CMC Firmware Image:
To get the firmware update status:
racadm fwupdate –s –m cmc-active
Invalid firmware: The uploaded firmware image does not contain a verification signature.
The following table describes the firmware update method supported for each interface.
FW Update Method
Local RACADM
Local RACADM-TFTP
Local RACADM-FTP
Remote RACADM
Remote RACADM-TFTP
Remote RACADM-FTP
Firmware RACADM-TFTP
Firmware RACADM-FTP

getactiveerrors

Description
Displays CMC active errors.
Synopsis
racadm getactiveerrors
racadm getactiveerrors [-s <severity>] [-m <module>]
Input
The command racadm getactiveerrors displays the critical, warning, and informational messages for all
the modules.The values are:
-s <severity> — Specifies the severity type message displayed. The command racadm
getactiveerrors displays the selected type of messages for all the modules. When used with -m option,
only selected message type for that module is displayed. The values for -s <severity> are:
critical
warning
info
-m <module> — Specifies the module for which the messages such as critical, noncritical (warning), and
informational are displayed. The command racadm getactiveerrors displays critical, noncritical
(warning), and informational messages for the selected module. When used with -s option, only selected
message type for the module is displayed. The values for -m <module> are:
server-<n> — where n=1–16
server-<nx> — where n=1–8; x = a, b, c, d (lower case)
switch-<n> — where n=1–6
NOTE: Firmware update from local RACADM (using -p -u -d options) is not supported on linux OS.
NOTE: These commands specifically apply to an active-CMC update.
CMC
No
No
No
Yes
Yes
Yes
Yes
Yes
27