Getdcinfo - Dell PowerEdge M1000e Reference Manual

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

If errors are not encountered, this subcommand displays the content of the specified configuration.
Displays the configuration properties (objects) that are contained in the group cfgLanNetworking.
Example
racadm getconfig -g cfgLanNetworking
Saves all group configuration objects from CMC to myrac.cfg.
racadm getconfig -f myrac.cfg
Displays a list of the available configuration groups on CMC in an alphabetical order.
racadm getconfig -h
Displays the configuration properties for the user named root.
racadm getconfig -u root
Displays the user group instance at index 2 with verbose information for the property values.
racadm getconfig -g cfgUserAdmin -i 2 -v
Displays an entire group of serial configuration.
racadm getconfig -g cfgSerial
Displays a single object from a particular group.
racadm getconfig -g cfgSerial -o cfgSerialBaudRate
Displays an indexed group.
racadm getconfig -g cfgUserAdmin -o cfgUserAdminUserName -i 2
Displays information about the session information for a particular server.
racadm getconfig -g cfgSessionManagement -m server-1
Displays information about the WEB/SSH/Telnet information for a particular server.
racadm getconfig -g cfgRacTuning -m server-1
Displays information about the remote Syslog for a particular server.
racadm getconfig -g cfgRemoteHosts -m server-1
Displays the current Enhanced Cooling Mode property configuration.
racadm getconfig –g cfgThermal

getdcinfo

Description
Displays general I/O module and daughter card configuration information. Only the CMC controls daughter
cards.
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getdcinfo
racadm getdcinfo [-n]
Input
-n — Displays the model names for the daughter cards in servers.
Example
The example output below is for a system with multi-slot servers:
racadm getdcinfo
Group A I/O Type : Gigabit Ethernet
Group B I/O Type : Gigabit Ethernet
Group C I/O Type : 10 GbE XAUI
NOTE: Fabric verification for server DCs is performed only when the chassis is turned on. When the
chassis is on standby power, iDRACs on the server modules remain turned off and thus are unable to
report the server's DC fabric type. The DC fabric type may not be reported in the CMC user interface
until iDRAC on the server is turned on.