Turn off the server 16 from CMC, when the power is already turned off on that server by using the
following command:
racadm serveraction -m server-16 powerdown
Server is already powered OFF.
•
Power action on all servers by using the following command:
racadm serveraction -a powerup
setarraycfg
Description
To configure storage array properties, run this command.
•
Synopsis
racadm setarraycfg -m module –n <member_name> <member_ip> <member_mask>
<member_gateway> -e 0|1 -g <groupname> <group_id> <group_password>
[<admin_password>] [-f A|B]
•
racadm setarraycfg -f A|B
NOTE: The valid value for -m is server–n, where n=1–16.
Input
•
-m — Module is one of the following values:
– server–<n>: where n = 1–7 and 9–15
•
<member_name> — A unique and descriptive name that is fewer than 64 alphanumeric characters,
without spaces. The first character is a letter or a number. It is used only to identify and administer the array.
•
<member_ip> — Each member IP Network address must have at least one network interface on the same
subnet as the group IP address.
•
<member_mask> — Member Netmask combines with the member IP address to identify the subnet on
which the network interface specified resides. The default is 255.255.255.0
•
<member_gateway> — Member Gateway network address is for the device that connects the subnet
and forward the network traffic beyond the local network.
•
—e — Selects existing or create new group for a member. The valid values are:
– 0 — to create new group
– 1 — to use existing group
•
<group_name> — Name of the group for administrative purpose. You can use up to 64 alphanumeric
characters and hyphens. The first character must be a letter or number.
•
<group_ip> — Group IP and Network address for the group. The group IP address is used for
administrative and host access to volumes.
•
<group_password> — Group Membership Management Password is required when adding members to
the group. The password must have 3 to 16 alphanumeric characters and is case-sensitive.
•
<admin_password> — Group Administration Password to set admin password when creating new group
and overrides the factory-set password. grpadmin is the default grpadmin account. The password must
have 3 to 16 alphanumeric characters and is case-sensitive.
•
—f — The valid values are A or B. Select Fabric used for data I/O. Options are:
– Fabric A (LOM port)
– Fabric B (mezzanine port)
The default is Fabric B. If the option is not specified, then the configuration is not done.
Output
<module> configuration was initiated successfully. It may take several minutes to complete.
•
Set member name, member IP, member netmask, member gateway with new group name, group IP, group
Example
password, admin password selecting fabric A on server-1.
racadm setarraycfg -m server-1 -n cmc-col 192.168.1.233 255.255.255.0
192.168.1.0 -e 0 -g cmc-array-grp 192.168.1.10 <password> -f A
NOTE: If —e is 0, then admin password is mandatory.
65