Dell PowerEdge M1000e Reference Manual page 26

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

– kvm
– server-<n> — where n=1–16
– server-<nx> — where n=1–8; x = a, b, c, d (lower case)
– server-<g> <generation> — where generation = iDRAC or iDRAC6 only.
– iominf-<n> — where n = 1–6
-f— Specifies the FTP server IP address or FQDN, username, and password used for firmware image.
Applies FTP download process for firmware update.
CMC version 3.00 accepts IPv4, IPv6 or fully qualified domain names (FQDN) for both FTP
and TFTP servers.
Displays a message indicating the operation that is being performed.
Output
Upload the firmware image from the TFTP server and start the firmware update.
Example
racadm fwupdate -g -u -a 192.168.0 -d firmimg.cmc -m cmc-active
TFTP firmware update has been initiated. This update process may take several minutes to complete.
Upload the firmware image from the FTP server and start the firmware update.
racadm fwupdate -f 192.168.0.100 fred xxx -d firmimg.cmc -m cmc-active
Upload a firmware image from the client and start firmware update.
racadm fwupdate -p -u -d firmimg.cmc
Start IOM infrastructure firmware update.
racadm fwupdate -u -m iominf-1
Update firmware on both the CMCs.
racadm fwupdate -g -u -a 192.168.0 -d firmimg.cmc -m cmc-active -m cmc-
standby
Update firmware on multiple servers.
racadm fwupdate -g -u -a 192.168.0 -d firmimg.imc -m server-1 -m server-2
-m server-3
Update firmware on servers of iDRAC generation.
racadm fwupdate -g -u -a 192.168.0 -d firmimg.imc -m server-iDRAC
Update firmware on multiple IOM infrastructure devices.
racadm fwupdate -u -m iominf-4 -m iominf-5 -m iominf-6
Query the status of all firmware targets to be updated.
racadm fwupdate -s -m all
Query the current status of the firmware update process for a particular module.
racadm fwupdate -s -m <module>
Download firmware update file from a specified location on the TFTP server at a specific IP address.
racadm fwupdate -g -u -a 192.168.0 -d <path>
After the image file is downloaded from the TFTP server, the update process begins. When completed,
CMC is reset.
Read the status of the firmware update.
racadm fwupdate -s
Cancel a firmware update in progress.
racadm fwupdate –c
26
NOTE: Multiple modules can be specified except iominf-<n>, for example, –m <module 1> –m
<module 2> and so on.
NOTE: You can specify the cmc-active and cmc-standby modules at the same time along with one or
more server-n modules. This option enables the devices to be updated together.
NOTE: Verify that the update applied to servers for a particular generation has been validated for all
impacted server models.

Hide quick links:

Advertisement

Table of Contents
loading