Tandy 1000 HX Technical Reference Manual page 55

Table of Contents

Advertisement

• TANDY COMPUTER PRODUCTS •
50
Bit4 = 0 &
OPERATION CONTROL WORD 2
Bit3 = 0
BitO - 2: Determine the interrupt level acted on
when the SL bit is active
I n t e r r u p t
Level
= 0 1 2 3 4 5 6 7
BitO ( L 0 ) :
0 1 0 1 0 1 0 1
B i t l
( L l ) :
0 0 1 1 0 0 1 1
B i t 2
( L 2 ) :
0 0 0 0 1 1 1 1
Bit5 - 7
Control Rotate and End of Interrupt
modes
B7
0
0
1
1
0
1
1
0
B6
0
1
0
0
0
1
1
1
B5
1
1
1
0
0
1
0
0
Non-specific EOI command
Specific EOI command
Rotate on non-specific EOI command
Rotate in Automatic EOI Mode (set)
Rotate in Automatic EOI Mode (clear)
*Rotate on Specific EOI command
*Set priority command
No operation
End of Interrupt
End of Interest
Automatic Rotation
Automatic Rotation
Automatic Rotation
Specific Rotation
Specific Rotation
*LO - L2 are used
Bit4 = 0 &
Bit3 = 1
OPERATION CONTROL WORD 3
BitO - 1:
Bitl BitO- Read Register Command
0
0 - No Action
0
1 - No Action
1
0 - Read IR Register on next IOR* Pulse
1
1 - Read IS Register on next IOR* Pulse
Bit2 = 0 :
No Poll Command
= 1: Poll Command
Bit5 - 6:
Bit6 Bit5- Special Mask Mode
0
0 - No Action
0
1 - No Action
1
0 - Reset Special Mask
1
1 - Set Special Mask
Bit7 = 0