Tandy 1000 HX Technical Reference Manual page 152

Table of Contents

Advertisement

TANDY COMPUTER PRODUCTS
2.0 ENVIROMENTAL SPECIFICATIONS
2.1 Storage temperature: -65°C min.,
+150°C max.
2.2 Operating temperature: 0°C min., +25°C typ
f
+70°C max.
3.0 DC ELECTRICAL SPECIFICATIONS
3.1 Absolute Maximum Rating:
Voltage on any pin
w.r.t. Ground:
-0.5 min., 7.0 max. volts
3.2 Operating Electrical Specifications:
Min.
Typ. Max. Units
3.2.1 Operating Ambient:
Air Temperatue Range
0
25
70 °C
3.2.2 Power Supplies:
VCC
4.5
5.0
5.5 volts
VSS
0
0
0 volts
ICC
milli-
amps
Total Power
milli-
watts
3.2.3 Leakage Current, All Inputs:
Vin = 0.0 v
-10
micro-
amps
Vin = 5.0 v
+10
micro-
amps
3.2.4 Input voltages:
3.2.4.1 Except RDDATA*, TRK*
Logic "0"
.8
volts
Logic "1"
2.0
volts
3.2.4.2 RDDATA*, TRK*
Positive going threshold
1.8
volts
Negative going threshold
1.2
volts
Hysteresis voltage
220
milli-
volts
3.2.5 Output Voltages:
3.2.5.1 Except WRDATA*, STEP*
Logic "0" @ 4.0 mA load
.4
volts
Logic "1" @ 4.0 mA load
2.4
volts
3.2.5.2 WRDATA*, STEP*
Logic "0" @ 48 mA
.5
volts
3.2.6 Input Capacitance (0.0 < Vin < 5.0)
All inputs
10 pf
3.2.7 Output Capacitance
All loads
50 pf