3.5
Power On and Power off Requirements
3.5.1
Data Protection
Turning
power
on
or
off
does not cause any damage to
recorded
data on the disk
as the drive
is not
in the
midst of writing when the power is shut off or supplied.
3.5.2
Power Supply Sequencing
No special supply sequencing is required by the disk drive
as long
as both
the 5V and
12V power
supplies have a
monotonic rise time of less than 100msec.
When the power is
turned
off, although
there are no
sequencing
or
timing
requirements, both power supplies must fall monotonically to
OV.
3.6
Disk motor rotation and Disk Insertion.
Even if the MOTOR ON signal is true (low) , the disk motor does
not rotate until a disk is inserted.
4. Safety
MP-F63W-00D will meet the following product safety regulations:
U.L. 478
C.S.A. C.22.2, No.154
U.L. 94V-0 for Front Bezel