Tandy 1000 HX Technical Reference Manual page 236

Table of Contents

Advertisement

11
TANDY COMPUTER PRODUCTS
ELECTRICAL SPECIFICATIONS - DMA
ELECTRICAL PARAMETERS
ABSOLUTE MAX RATINGS (NON-OPERATING, VSS=0.0V)
MIN
MAX
UNITS
STORAGE TEMPERATURE
-65
+150
DEGREES C.
VOLTAGE ON ANY PIN
-0.5
7.0
VOLTS
W.R.T.GROUND
OPERATING ELECTRICAL SPECIFICATIONS:
OPERATING AMBIENT
MIN TYP
MAX
UNITS
AIR TEMP. RANGE
0
25
70
DEGREES C
POWER SUPPLIES
VDD
4.5
5.0
5.5 VOLTS
VSS
0
0
0
VOLTS
ICC
100
MILLIAMPS
NOTE:
INCLUDE ALL RELEVENT CONDITIONS UNDER WHICH ICC IS
TO BE MEASURED; IE, ALL INPUTS AT VSS OR VCC, CLOCK
FREQUENCY, ETC.
TOTAL POWER DISSIPATION
700
MILLIWATTS
(Include output loading)
LEAKAGE CURRENT
MIN
TYP
MAX
Vin = 0.0 v
20
microamps
Vin = 5.0 v
-20
microamps
INPUT VOLTAGES
LOGIC "0" (Vil)
0.8
volts
LOGIC "1" (Vih)
2.0
volts