Tandy 1000 HX Technical Reference Manual page 9

Table of Contents

Advertisement

TANDY COMPUTER PRODUCTS
SPECIFICATIONS
Processor:
Intel 8088-2
Dimensions:
3 1/4 x 17 x 14 1/2 (HWD)
Weight:
11 lbs
Power Requirements:
120 VAC, 60 Hz
With 3 1/2" Disk Drives, Memory Cards, and RS-232:
AC Current: 0.7 - 0.8 Amps with Floppy doing R/W tests.
Leakage Current: 0.5 mA
Power Supply Output:
+5 VDC 3.0 Amps max., 1.9 Amps Typ.
+12 VDC 2.0 Amps max. 1.2 Amps continuous
-12 VDC .1 Amp max.
Environment:
Air Temperature
System ON: 55 to 85 degrees F (13 to 30 degrees C)
System OFF: -40 to 150 degrees F ( - 4 0 to 69
degrees C)
Humidity:
System ON-OFF: 8% to 80%
Disk Drive Specifications
Power:
Supply
Voltage
+5 VDC Input
Ripple
0 to 50 kHz
0.1 Vpp
Tolerance
Including Ripple +/-5%
Standby Current
Nominal
50 mA
Average Current
(Read)
Peak Current
(Motor Start)
Peak Current
(Stepping during Motor On)
Operating Current
Nominal
240 mA
+12
0.1
0.3
130
500
450
VDC Input
Vpp
mA
mA
mA
mA

Hide quick links: