2.4
Input Power Requirements
2.4.1
Power Consumption
TTL Interface
Standby
250 mW
Operation (read/write mode)
2.8 W
2.4.2
Supply Voltages
Voltage
Max. Ripple
Current
+12.0V +/-5%
O.lVpp
Standby
0.3 mA
Average
130 mA
(Read)
Peak
500 mA
(Motor Start)
Peak
450 mA
(stepping during Motor On)
+5.0V +/-5%
O.lVpp
Standby
50 mA
Operating 240 mA
2.5
Environmental Limits
2.5.1
Temperature Range
Operating
: 5°C to 50°C ambient (40°F to 122°F)
Transportation
: -40°C to 60°C
(-40°F to 140°F)
Storage
: -20°C to 60°C
(-20°F to 140°F)
2.5.2
Humidity Range
Operating
: 8% to 80% relative humidity with a wet bulb
temperature
of
29°C
(85F)
and
no
condensation.
Transportation
and Storage
: 5% to 95% relative humidity and no
condensation
2.5.3
Vibration
Operating
: The unit can perform Read/Write operations
without
errors
at
continuous
vibration
from 10 to 500 Hz at a maximum of 0.5G
along each of the three mutually
perpendicular axes.
Transportation
and Storage
: The unit can withstand continuous vibration
from
10 to 300 Hz with
a maximum
level
of 2.0G along each of the three mutually
perpendicular axes without any degradation
of any characteristics below the
performance specifications.
Page 7