Sgdv- E1A (Command Option Attachable Type); Other Precautions - YASKAWA SGDV User Manual

Ac servo drives. e-v series. rotational motor
Hide thumbs Also See for SGDV:
Table of Contents

Advertisement

2.4.4
SGDV-
For SERVOPACKs of command option attachable type, EMC installation conditions
may differ depending on the attached option module. For details, refer to the user's
manual for each option module.
2.4.5

Other Precautions

Attachment Methods of Ferrite Cores
Recommended Ferrite Core
Cable Name
Motor main circuit cable
Recommended Noise Filter and Surge Absorber
For more information on recommended noise filters and surge absorbers, refer to
Series Product Catalog (literature no.: KAEP S800000 42).
Fixing the Cable
Fix and ground the cable shield using a piece of conductive metal.
• Example of Cable Clamp
Host controller side
Shield Box
A shield box, which is a closed metallic enclosure, is effective as reinforced shielding
against electromagnetic interference (EMI) from SERVOPACKs. The structure of the
box should allow the main body, door, and cooling unit to be attached to the ground.
The box opening should be as small as possible.
<Note>
Do not connect the digital operator and the analog monitor cable to the SERVOPACK
during operations. Connect them only when the machinery is stopped during mainte-
nance.
E1A (Command Option Attachable Type)
One turn
Cable
Ferrite core
Ground plate
2.4 EMC Installation Conditions
Two turn
Cable
Ferrite core
Ferrite Core Model
ESD-SR-250
Cable
Shield (cable sheath stripped)
Fix and ground the cable shield
using a piece of conductive metal.
Cable
clamp
Remove paint on mounting surface.
Manufacturer
NEC TOKIN Corp.
Σ
-V
2
2-37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmavSgmjvSgmsvSgmpsSgmgv

Table of Contents