Wiring Procedure
1.
Remove the main circuit terminal connector from the SERVOPACK.
Lock
2.
Strip the end of the wires.
3.
Open the wire terminal on the terminal connector housing with a tool,
using the following methods. Either method can be used to open the
wire terminal.
Using a spring opener
Use the spring opener provided with the SERVOPACK to open the wire terminal as
shown in the diagram.
Note: The spring opener (1981045-1) made by Tyco Electronics AMP K.K. can also be used.
1 Press
the lock.
Main circuit
terminal connector
Applicable wire sizes:
Refer to 3.3.2 SERVOPACK
Main Circuit Wire Size.
8 to 9 mm
Spring opener
Wire
3.3 Main Circuit Wiring
Enlarged View
2. Remove the main
circuit terminal
connector while
pressing the lock.
3-29