YASKAWA SGDV User Manual page 101

Ac servo drives. e-v series. rotational motor
Hide thumbs Also See for SGDV:
Table of Contents

Advertisement

5 Trial Operation (Checking Servomotor Operation)
Installing the Servomotor and SERVOPACK
Install the servomotor and SERVOPACK according to the installation conditions.
<Note>
• Be sure to secure the servomotor to the equipment, or the servomotor may turn
over when it starts rotating.
• Do not connect anything to the servomotor shaft.
Checking the Main Circuit Power Supply, Servomotor, and Encoder
Wiring
Once again, check the main circuit power supply, servomotor, and encoder wiring
that was described in Chapter 3 Wiring and Connection.
Perform a trial operation with the safety function jumper connector (JZSP-CVH05-E,
provided as an accessory) inserted into the CN8 connector.
5-4
Power supply
Safety function jumper connector
(JZSP-CVH05-E)
Do not connect to CN1.
Secure the mounting plate of
the servomotor to the
equipment.
Do not connect any load to the shaft.
Encoder cable

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmavSgmjvSgmsvSgmpsSgmgv

Table of Contents