Three-phase 400 V
• SGDV-
Power supply:
5
Single-phase
200 VAC
Surge
absorber
6
Power supply:
Three-phase
400 VAC
PE
MECHATROLINK-III
controller
7
Symbol
∗1.
Products that have received CE marking are recommended for the 24 VDC power supply.
∗2.
Install the following noise filter on the power line between the single-phase 200 V power
supply and the 24 VDC power supply.
Model number: FN2070-6/07 (SCHAFFNER)
∗3.
For more information on this filter, refer to
KAEP S800000 42).
D21A (
= 1R9, 3R5, 5R4, 8R4, 120, 170)
Control
Noise
power
supply
filter*
2
24 VDC*
1
Noise
filter*
3
Surge
absorber
Two turn
Host controller
Cable Name
I/O signal cable
Safety signal cable
Motor main circuit cable
Encoder cable
Control power cable
Main circuit cable
MECHATROLINK-III communication cable Shield cable
2.4 EMC Installation Conditions
Shield box
Brake Power
Supply
SERVOPACK
24 V,
U, V, W
0 V
L1, L2, L3
CN2
One turn
CN6A, CN6B
CN1
CN8
Core
Core
Clamp
Clamp
1
2
Safety unit
Shield cable
Shield cable
Shield cable
Shield cable
Shield cable
Shield cable
Σ
-V Series Product Catalog (literature no.:
Brake
3
Servomotor
One turn
4
Encoder
One turn
PE
Two turn
Specification
2
2-35