Saving Data - Komatsu 830E Shop Manual

Dump truck
Hide thumbs Also See for 830E:
Table of Contents

Advertisement

Note: The changes made above are only temporary.
When
the
proper
adjustment value
determined, the truck configuration file should be
permanently changed by entering this value on the
TRUCK
SPECIFICS
SCREEN.
accessed by returning to the GE OHV STATEX III
MENU, selecting "TRUCK SETUP (CFG)", and then
line 5); "Change/view Truck Specifics".
"TEMPORARY EVENT DATA COLLECTION INTER-
VAL"
This feature will allow changing the event data collec-
tion interval to a more frequent or less frequent period.
This feature may be necessary during troubleshooting
procedures to capture system operation over a differ-
ent time period other than normally used.
1. Select "EVENT DATA COLLECTION INTERVAL"
from the TEMPORARY TRUCK SETTINGS
MENU and press [ENTER].
2. Type the desired interval on the TEMPORARY
EVENT
DATA
COLLECTION
SCREEN.
Note: This new setting will remain in effect until it is
changed again on this screen or when power is cycled
on and off.
3. Move the cursor to select ACTIVATE TEMPO-
RARY EVENT DATA COLLECTION INTERVAL
and press [ENTER].
E2-60
MISCELLANEOUS FEATURES
has
been

SAVING DATA

Various screens showing event data, digital input and
This
screen
is
output test data, real time data, etc. can be saved to
the PTU.
Many screens will have a selection labelled "GET1".
When selected, the data gathered and displayed on the
screen will be suspended and can then be saved per-
manently to a file. If this selection is available, it should
be chosen before pressing [F2] to save to a file.
To use this feature:
1. When it is desired to save the screen display,
2. Press [F2] to save the screen to a file.
INTERVAL
3. Selecting "GET1" again will update the screen
4. To resume and allow the data to be continuously
If the "GET1" selection is not available, the [F2] key is
used to save the screen display when applicable. The
availability of the [F2] key for saving the data will be
shown at the bottom of the screen.
Electrical Propulsion Components
select "GET1" using the arrow keys and press
[ENTER].
a. Follow the screen instructions for assigning a
file name and location for storing the file.
b. After the file has been saved, the PTU screen
data will remain suspended until the next step
is completed.
with new data and hold it there. Step 2. may be
repeated to save the updated data if desired.
updated, move the cursor to "REPEAT" and
press [ENTER].