9. With throttle pedal fully depressed, measure the following:
CIRCUIT
ACC CARD
TZ6661
510(+)
to
EB2635
952(-)
EC1806
10. Release throttle pedal.
11. Measure voltage at circuit 525 and 952 while slowly pressing throttle pedal from minimum to full
throttle.
For adjustable pedal with TZ6661/EB2635 card, meter reading should start from approx-
imately 0.70 vdc and increase to approx. 4.35 vdc in a smooth and linear fashion.
mately 0.54 vdc and increase to approximately 4.30 vdc in a smooth and linear fashion.
If there are positions of voltage drop off, replace pedal potentiometer.
12. Release throttle pedal. Measure circuits 73R to 710 with pedal released.
Measure 0.0 vdc.
13. Depress throttle pedal fully. Measure circuits 73R to 710 with pedal pressed fully.
Measure approximately 26.0 vdc.
14. Release pedal. If step 12 or 13 readings are incorrect, replace accelerator card.
1.1.2 Electronic Throttle System (Fuel Saver System).
NOTE: Instructions are also included in the following procedure for retard pedal setup which can
be performed in conjunction with accelerator pedal setup on trucks equipped with the "Fuel Saver"
circuitry.
Turn Key Switch and Control Power On.
Set up PTU as described previously using the communication port in the electrical cabinet.
Start the GE software program be typing "gemenu3e" if using Statex III Enhanced version 1.00
software (or type "gemenu" if using version 14.00 software) from the DOS C:> prompt.
a. From the GEOHV STATEX III MENU, select "PTU TALK TO TRUCK" and press [ENTER].
b. At PTU LOGON screen, enter your name and assigned password. Press [ENTER].
c. When the GE STATEX III PTU MAIN MENU appears (Figure 3-4), move the cursor to "NOR-
MAL OPERATION" and press [ENTER].
d. A screen appears with the message: "Selection of NORMAL OPERATION gives truck con-
trol to the driver - Continue?". With the cursor at the "Yes" option, press [ENTER].
e. The NORMAL OPERATION MENU will appear. Select "MONITOR ANALOG INPUT CHAN-
NELS" and press [ENTER]; the screen shown in Figure 3-5. will appear.
E3-6
VOLTS
3.80 (approx.)
4.35 (approx.)
4.05 (approx.)
For non-adjustable pedal with EC1806 card, meter reading should start from approxi-
Statex III Electrical Checkout Procedure
ACTION IF OUT
PTO COUNTS
OF TOLERANCE
203 -4/ +10
Replace ACC card or
215 -4/ +10
pedal
215 -4/ +10