4. MOTOR 2 SPEED . . . . . . . . . . . . . . . . . . . . . . Motor 2: 0.0 rpm; 0.0 mph
a. Connect oscillator to circuits 714 and 714A at control cabinet terminal board. Repeat same
test procedure for Motor 2 as used for Motor 1.
5. CONVERSION FACTOR - RPM TO MPH. . . . . . . . rpm x 0.00000 = mph
Value displayed 0.00000 is conversion factor to convert from wheelmotor rpm to mph. Com-
pare value displayed with value given in MAXIMUM TRUCK SPEED CHART. (Refer to "Miscel-
laneous Charts; Maximum Allowable Truck Speeds.")
Return to Main Menu
1. This completes Analog and Frequency Input Checks.
2. Move cursor to select "EXIT" on the menu and press [ENTER] key.
3. Select "EXIT" as necessary until returned to GE STATEX III PTU MAIN MENU.
4. Move cursor to select "EXIT" on this menu and press [ENTER] key.
5. At "QUIT PTU?" menu screen prompt , press [Y] key (or any key except [N]) to exit back to the
GE OHV STATEX III MENU.
6. Turn control power switch Off.
7. Turn key switch Off.
E03012 2/02
Statex III Electrical Checkout Procedure
E3-33