Komatsu 830E Shop Manual page 213

Dump truck
Hide thumbs Also See for 830E:
Table of Contents

Advertisement

PAR
DESCRIPTION
No.
AFSE Temp ° C
98
(in seconds)
MFSE Temp °C
99
(in seconds)
E02016 2/02
TABLE IV. STATISTICAL DATA CODES - PROFILES (Cont.)
COUNT CONDITIONS
This is a histogram of Alternator Field Static Exciter temperature.
. . . . Sample time is 60.0 seconds
. . . . The clock will start whenever control power (CPR) is on.
The histogram breaks the temperature spectrum into 17 buckets
defined at right, and displays the time spent in each bucket.
This is a histogram of Motor Field Static Exciter temperature.
. . . . Sample time is 60.0 seconds
. . . . The clock will start whenever control power (CPR) is on.
The histogram breaks the temperature spectrum into 17 buckets
defined at right, and displays the time spent in each bucket.
Electrical Propulsion Components
TEMP RANGE
BUCKET No.
(° C)
1
20 & below
2
21 to 40
3
41 to 50
4
51 to 60
5
61 to 70
6
71 to 80
7
81 to 90
8
91 to 100
9
101 to 105
10
106 to 110
11
111 to 120
12
121 to 125
13
126 to 130
14
131 to 135
15
136 to 140
16
141 to 145
17
146 & above