Komatsu 830E Shop Manual page 168

Dump truck
Hide thumbs Also See for 830E:
Table of Contents

Advertisement

EVENT
EVENT
CODE
DESCRIPTION
12
MF Contactor
13
P1 Contactor
14
P2 Contactor
17
RP1 Contactor
18
RP2 Contactor
19
RP3 Contactor
20
RP4 Contactor
21
RP5 Contactor
22
RP6 Contactor
23
RP7 Contactor
E2-12
TABLE I. 2-DIGIT DISPLAY PANEL CODES (Cont.)
EVENT RESTRICTION
System Event
• In ACCEL: No propel and
turn on SYSFLT light.
• In RETARD: Turn on SYS-
FLT light only.
System Event
• In ACCEL: No propel and
turn on SYSFLT light.
• In RETARD: Turn on SYS-
FLT light only.
System Event
• In ACCEL: No propel and
turn on SYSFLT light.
• In RETARD: Turn on SYS-
FLT light only.
System Event
• In ACCEL: No propel and
turn on SYSFLT light.
• In RETARD: Turn on SYS-
FLT light only.
System Event
• In ACCEL: No propel and
turn on SYSFLT light.
• In RETARD: Turn on SYS-
FLT light only.
System Event
• In ACCEL: No propel and
turn on SYSFLT light.
• In RETARD: Turn on SYS-
FLT light only.
System Event
• In ACCEL: No propel and
turn on SYSFLT light.
• In RETARD: Turn on SYS-
FLT light only.
System Event
• In ACCEL: No propel and
turn on SYSFLT light.
• In RETARD: Turn on SYS-
FLT light only.
System Event
• In ACCEL: No propel and
turn on SYSFLT light.
• In RETARD: Turn on SYS-
FLT light only.
System Event
• In ACCEL: No propel and
turn on SYSFLT light.
• In RETARD: Turn on SYS-
FLT light only.
Electrical Propulsion Components
DETECTION
Decay
INFORMATION
MF Contactor command and
feedback do not agree.
Check for: Same as No. 10.
P1 Contactor command and
feedback do not agree.
Check for: Same as No. 10.
P2 Contactor command and
feedback do not agree.
Check for: Same as No. 10.
RP1 Contactor command
and feedback do not agree.
Check for: Same as No. 10.
RP2 Contactor command
and feedback do not agree.
Check for: Same as No. 10.
RP3 Contactor command
and feedback do not agree.
Check for: Same as No. 10.
RP4 Contactor command
and feedback do not agree.
Check for: Same as No. 10.
RP5 Contactor command
and feedback do not agree.
Check for: Same as No. 10.
RP6 Contactor command
and feedback do not agree.
Check for: Same as No. 10.
RP7 Contactor command
and feedback do not agree.
Check for: Same as No. 10.
EVENT VALUES
Lock
Accept
Window
Time
Limit
Limit
3600
3
10
3600
3
10
3600
3
10
3600
3
10
3600
3
10
3600
3
10
3600
3
10
3600
3
10
3600
3
10
3600
3
10
2/02 E02016
Limit
2
2
2
2
2
2
2
2
2
2

Advertisement