EVENT
EVENT
CODE
DESCRIPTION
Motor 1
46
Overcurrent
Motor 2
47
Overcurrent
48
Motor Field Fault
Motor Field
49
Overcurrent
50
Motor Stall
51
Motor Spin
Alternator
52
Tertiary
Overcurrent
Motor Tertiary
53
Overcurrent
E2-14
TABLE I. 2-DIGIT DISPLAY PANEL CODES (Cont.)
EVENT RESTRICTION
System Event
Current in Motor 1 armature
• In ACCEL: No propel and
exceeds limits for a preset
turn on SYSFLT light.
time. Limit is a function of
• In RETARD: Turn on SYS-
being in retard or accelera-
FLT light only.
tion.
System Event
Current in Motor 2 armature
• In ACCEL: No propel and
exceeds limits for a preset
turn on SYSFLT light.
time. Limit is a function of
• In RETARD: Turn on SYS-
being in retard or accelera-
FLT light only.
tion.
Motor field current not in cor-
System Event
rect proportion with motor
• In ACCEL: No propel and
armature current.
turn on SYSFLT light.
Check for defective shunt,
• In RETARD: Turn on SYS-
iso-amp, wiring, FB102/140
FLT light only.
card.
System Event
Current in motor fields
• In ACCEL: No propel and
exceeds limits. Limit is a
turn on SYSFLT light.
function of being in retard or
• In RETARD: Turn on SYS-
acceleration.
FLT light only.
Motors stalled with motor
current above 1000 amps,
System Event
inverse time function. Could
• In ACCEL: No propel and
be caused by overloaded
turn on SYSFLT light.
truck, grade or rolling resis-
• In RETARD: Turn on SYS-
tance too high.
FLT light only.
Check for defective speed
sensors, shunts, iso-amps,
wiring, FB102/140 card.
System Event
One motor stuck, the other
• In ACCEL: No propel and
spinning for longer than 10
turn on SYSFLT light.
seconds with motor current
• In RETARD: Turn on SYS-
>100A.
FLT light only.
Check for: Same as No. 50.
System Event
Current in alternator field ter-
• In ACCEL: No propel and
tiary windings exceeds lim-
turn on SYSFLT light.
its for a preset time.
• In RETARD: Turn on SYS-
Check for shorted diodes or
FLT light only.
SCRs in AFSE.
Current in motor field tertiary
System Event
windings exceeds limits for a
• In ACCEL: No propel and
preset time.
turn on SYSFLT light.
Check for shorted diodes or
• In RETARD: Turn on SYS-
SCRs in MFSE.
FLT light only.
Check for low engine rpm in
retarding.
Electrical Propulsion Components
DETECTION
Decay
INFORMATION
Time
3600
3600
3600
3600
3600
3600
N/A
N/A
EVENT VALUES
Lock
Accept
Window
Limit
Limit
Limit
3
10
2
3
10
2
3
10
4
3
10
4
3
10
2
3
10
4
1
4
2
1
4
2
2/02 E02016