EVENT
EVENT
CODE
DESCRIPTION
Alternator Field
83
Current Level
88
Lamp Test
90
Battery Volts Low
91
Battery Volts High
Bad Engine
92
Sensor
98
Data Store
99
Software
E02016 2/02
TABLE I. 2-DIGIT DISPLAY PANEL CODES (Cont.)
EVENT RESTRICTION
Recorded in memory only.
None
System Event
• In ACCEL: No propel and
turn on SYSFLT light.
• In RETARD: Turn on SYS-
FLT light only.
Recorded in memory only.
Recorded in memory only.
Recorded in memory.
Recorded in memory.
Electrical Propulsion Components
DETECTION
INFORMATION
Alternator field current slow
to decay.
Check for: Defective shunt,
iso-amp, or FB102/140 card.
Lamp test in progress.
• Not a true event.
• Not logged.
Battery volts low. Less than
21 volts for 4 seconds and
engine speed greater than
600 rpm.
Check for: Check 24V alter-
nator or batteries.
Battery volts high. Greater
than 32 volts for 4 seconds.
Check 24V alternator regula-
tor.
Engine sensor output outside
normal range.
Check sensor and wiring.
Indicates a data snapshot
has been initiated by manual
means.
Software problem. The allo-
cated fault registers in mem-
ory are full, insufficient space
exists.
Reset event list, erase
events.
EVENT VALUES
Decay
Lock
Accept
Window
Time
Limit
Limit
N/A
N/A
10
3600
3
10
N/A
N/A
10
N/A
N/A
10
N/A
N/A
11
1800
3
5
Limit
1
2
1
3
10
1
E2-17