FB220 STL (Continued)
:T
FW 204
:T
FW 206
:T
FW 208
:T
FW 210
:T
FW 212
:T
FW 214
:T
FW 216
:T
FW 218
:T
FW 220
:BE
OB1 STL
:JU
FB
1
NAME :SEND
:
:JU
FB
2
NAME :RECEIVE
:BE
FB1 STL
NAME :SEND
:C
DB 203
:O
F
:ON
I
:BEC
:
:A
F
:JC
PB
:
:
:L
KF +10
:T
DW
:
:L
DW
:ADD KF +1
:T
DW
:
:AN
F
:S
F
:BE
EWA 4NEB 811 6130-02b
RESET FLAG AREA
SEND
RECEIVE
CALL DB CONTAINING SEND MAILBOX
100.7
GO TO END WHEN SEND IN PROGRESS
0.0
OR WHEN NO SEND REQUEST IS PENDING
(ENABLE SEND WITH I 0.0)
100.0
ERROR DURING LAST SEND?
1
THEN EVALUATE ERROR IN PB1
LOAD DATA INTO SEND MAILBOX
10 BYTES ARE TO BE TRANSFERRED
0
(FIRST WORD IN SEND MAILBOX)
1
MODIFY END DATA
1
100.7
INITIATE SEND
100.7