Siemens SIMATIC S5-115U User Manual page 416

Simatic s5 series cpu 941-7ub11 cpu 942-7ub11 cpu 943-7ub11 and cpu 943-7ub21 cpu 944-7ub11 and cpu 944-7ub21
Table of Contents

Advertisement

Integral Blocks
FB10
STL
NAME :REGLER 1
:
:C
DB
30
:
:
:
:
:
:L
PY
0
:T
FY
10
:T
DR
11
:
:
:
:
:
:
:
:
:
:
:
:
:A
F
12.0
:R
F
12.0
:AN
F
12.1
:S
F
12.1
:
:JU
FB 250
NAME :RLG:AE
BG
:
KF +128
KNKT :
KY 0,6
OGR
:
+2047
UGR
:
-2047
EINZ :
F
12.0
XA
:
DW
22
FB
:
F
12.2
BU
:
F
12.3
TBIT :
F
12.4
:
:
:JU
FY 250
11-42
Description
SELECT CONTROLLER'S DB
********************************
READ CONTROLLER'S CONTROL BITS
********************************
READ CONTROLLER'S
CONTROL INPUTS
AND STORE IN DR11
CAUTION:
DL11 CONTAINS IMPORTANT CONTROL
DATA FOR OB 251
THE CONTROL BIT MUST
THEREFORE BE TRANSFERRED WITH
T DR11 TO PREVENT
CORRUPTING DL11
********************************
READ ACTUAL VALUE AND SETPOINT
********************************
FLAG 0 (FOR UNUSED FUNCTIONS
IN FB250)
FLAG 1
READ ACTUAL VALUE
MODULE ADDRESS
CHANNEL NO. 0, FIXED-POINT BIPOLAR
UPPER LIMIT FOR ACTUAL VALUE
LOWER LIMIT FOR ACTUAL VALUE
NO SELECTIVE SAMPLING
STORE SCALED ACTUAL VAL. IN CONTR. DB
ERROR BIT
RANGE VIOLATION
ACTIVITY BIT
READ SETPOINT
S5-115U Manual