The inverter uses a battery temperature sensor to adjust charge
voltage. When the battery temperature rises the sensor sends this
information to the inverter to decrease charge voltage. Voltage
compensation with temperature variation is necessary to keep charge voltage
at optimum values. The sensor is secured to the terminal of the battery.
Battery Capacity and Idle Mode are adjustable. The program mode must
be entered to change a setting.

To Enter the Programming Mode:

• Press and hold the SETUP button for five seconds. LED lamps
will change from green to red.
• If a setting change does not occur within five seconds, the
remote returns to the user menu.
• Use the Remote Owner's Manual to cross-reference the LED
lights to their respective indication.
Idle Mode:
Setting the IDLE mode controls the threshold (in watts) that turns the
inverter on from search mode. The adjustment range is 5 to 100 watts. The
factory setting is five watts. Press the INVERT button to change the settings.
Battery Capacity:
Setting the proper battery capacity tailors the internal charger to optimum
values. The Factory setting is 400. Press the CHARGE button to change the
settings.
The AC distribution panel is located in the bedroom. The main AC panel
120 Volt circuit breakers receive power from the transfer switch, which is
powered by either shore power or the on board
generator. Power is introduced into the panel to the 50 Amp MAIN breaker
first, followed by power being fed into the individual branch circuit breakers.
The panel label describes the breaker layout and the item, outlet or appliance
to which they pertain.