LP Tank Operation

050265c
LP-GAS
FUNDAMENTALS
7 • 278
• Manually open the primary shut-off valve located on the LP-Gas tank.
• Turn on the electric valve to allow gas to flow to the appliances.
• Turn off the electric valve and primary valve on the LP-Gas tank when
the tank is being filled, in between trips and when in storage.
• Hand-tighten the primary valve only. Do not use a wrench or pliers, as
this will over-tighten the valve. The primary valve is designed to be
closed by hand, over-tightening may permanently damage the valve
seat.
# Capacity Gallon Capacity BTU Capacity
5
10
11
20
30
40
Gallons to Liters
Fahrenheit to Celsius
11 in. Water Column = 6 1/4 ozs. per sq. in. pressure.
27.7 in. Water Column = 1 lb. per sq. in. pressure.
The above capacities allow for 20% vapor space on each cylinder.
Data taken from the National Fire Prevention Association (NFPA). Pamphlet #58-1998.
1.18
2.36
2.59
4.72
7.08
9.43

CONVERSIONS

(1 Gallon = 3.785 Liters)
(F° - 32 ÷ 1.8 = C°)
LP-GAS SYSTEM
om050238b
107,903
215,807
237,387
431,613
647,420
863,226